    EU Amends the Exemption for Lead and Cadmium in Annex III of RoHS Regulation

    21 November 2018, EU released 18 directives to amend the exemption for lead content in Annex III of EU RoHS Regulation. This Directive shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.

    The detail of the amending is as follows:

    Exemption
     
    Scope and dates of applicability
    7(c)-IV Lead in PZT based dielectric ceramic materials for capacitors which are part of integrated circuits or discrete semiconductors Expires on:

    – 21 July 2021 for categories 1-7 and 10;

    – 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    – 21 July 2023 for category 8 in vitro

    medical devices;

    – 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.”

    (c)-II Lead in dielectric ceramic in capacitors for a rated voltage of 125 V AC or 250 V DC or higher Does not apply to applications covered by point 7(c)-I and 7(c)-IV of this Annex. Expires on:

    – 21 July 2021 for categories 1-7 and 10;

    – 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    – 21 July 2023 for category 8 in vitro diagnostic medical devices;

    – 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

    8(b) Cadmium and its compounds in electrical contacts Applies to categories 8, 9 and 11 and expires on:

    ‒ 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    ‒ 21 July 2023 for category 8 in vitro diagnostic medical devices;

    ‒ 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

    15 Lead in solders to complete a

    viable electrical connection

    between semiconductor die and carrier within integrated circuit flip chip packages

    Applies to categories 8, 9 and 11 and expires on:

    ‒ 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    ‒ 21 July 2023 for category 8 in vitro diagnostic medical devices;

    ‒ 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

    15(a) Lead in solders to complete a viable electrical connection between the semiconductor die and carrier within integrated circuit flip chip packages where at least one of the following criteria applies:

    ‒ a semiconductor technology node  of 90 nm or larger;

    ‒ a single die of 300 mm2 or larger in any semiconductor technology node;

    ‒ stacked die packages with die of 300 mm2 or larger, or silicon interposers of 300 mm2 or larger.

    Applies to categories 1 to 7 and 10 and expires on 21 July 2021.”
    18(b) Lead as activator in the fluorescent  powder (1% lead by weight or less) of discharge lamps when used as sun tanning lamps containing phosphors such as BSP  (BaSi2O5:Pb) Expires on:

    ‒ 21 July 2021 for categories 1-7 and 10;

    ‒ 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    ‒ 21 July 2023 for category 8 in vitro diagnostic medical devices;

    ‒ 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

    18(b)-I Lead as activator in the fluorescent  powder (1 % lead by weight or less) of discharge lamps containing phosphors such as BSP (BaSi2O5:Pb) when used in medical phototherapy equipment Applies to categories 5 and 8, excluding applications covered by entry 34 of Annex IV, and expires on 21 July 2021.”
    21 Lead and cadmium in printing inks  for the application of enamels  on glasses, such as borosilicate and  soda lime glasses Applies to categories 8, 9 and 11 and expires on:

    ‒ 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    ‒ 21 July 2023 for category 8 in vitro diagnostic medical devices;

    ‒ 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

    21(a) Cadmium when used in color printed glass to provide filtering functions, used as a component in lighting applications installed in displays and control panels of EEE Applies to categories 1 to 7 and 10 except applications covered by entry 21(b) or entry 39 and expires on 21 July 2021.
    21(b) Cadmium in printing inks for the application of enamels on glasses, such as borosilicate and soda lime glasses Applies to categories 1 to 7 and 10 except applications covered by entry 21(a) or 39 and expires on 21 July 2021.
    21(c) Lead in printing inks for the application of enamels on other than borosilicate glasses Applies to categories 1 to 7 and 10 and expires on 21 July 2021.”
    29 Lead bound in crystal glass as defined in Annex I (Categories 1, 2, 3 and 4) of Council Directive 69/493/EEC * Expires on:

    ‒ 21 July 2021 for categories 1-7 and 10;

    ‒ 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    ‒ 21 July 2023 for category 8 in vitro diagnostic medical devices;

    ‒ 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

    “37 Lead in the plating layer of high voltage diodes on the basis of a zinc borate glass body Expires on:

    ‒ 21 July 2021 for categories 1-7 and 10;

    ‒ 21 July 2021 for categories 8 and 9 others than in vitro diagnostic medical devices and industrial monitoring and control instruments;

    ‒ 21 July 2023 for category 8 in vitro diagnostic medical devices;

    ‒ 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.”

    42 Lead in bearings and bushes of diesel or gaseous fuel powered internal combustion engines applied in non-road professional use equipment:

    ‒ with engine total displacement ≥ 15 litters; or

    ‒ with engine total displacement < 15 litters and the engine is designed to operate in applications  where the time between the signal to start and full load is required to be less than 10 seconds; or regular maintenance is typically performed in a harsh and dirty outdoor environment, such as  mining, construction, and agriculture applications.

    Applies to category 11, excluding applications covered by entry 6(c) of this Annex. Expires on 21 July 2024.

    For more information see

     

    360Compliance provides Testing & Certification for type approval services and global market access in 195 countries. With proven expertise in worldwide regulations, 360Compliance can help your company shorten time to any market, minimize risks and manage the regulatory process from A-Z.

    Share this:

    You may also be interested

    Cambodia-TRC
    Cambodia TRC Regulatory Updates
    March 21, 2024
    On December 11th, 2023, the head leader of Cambodia's Telecommunication Regulator of Cambodia (TRC) issued a notification to all officers regarding the review of type approval documents, emphasizing the importance of consistency between the information provided in test reports and that submitted by clients. This notification clarified that previously accepted practices, such as using the product name and country of origin as claimed by the client, should now align precisely with the details presented in the test report. Following discussions and confirmations, TRC officers reaffirmed on December 27th, 2023, that this new rule must be adhered to for all future projects seeking type approval. For submissions with one country of origin, the test report must indicate the CoO. In cases where a product has more than one country of origin, the report should display one CoO, with any additional CoOs declared in a separate declaration letter. Moreover, TRC explicitly stated that reports lacking any indication of country of origin will not be accepted under these new guidelines. This adjustment aims to enhance accuracy and consistency in reviewing type approval submissions. Streamlining TRC Type Approval with Support from 360Compliance 360Compliance specializes in navigating TRC's type approval process, ensuring documents precisely reflect the country of origin per the latest guidelines. Our team offers expert advice and comprehensive services, including preparing test reports and submitting declaration letters. Partner with us to meet TRC's stringent criteria, minimize delays, and effectively secure type approval for your products. Let 360Compliance handle the complexities of compliance, allowing you to focus on your core business activities with peace of mind. Contact us today to learn more about our services and how we can help you achieve regulatory compliance in Cambodia.
    SIRIM_MCMC_Certification
    Malaysia SIRIM-MCMC Regulatory Updates
    March 21, 2024
    The Malaysia SIRIM CMCS Department, responsible for MCMC certification, recently implemented a significant update regarding Intellectual Property (IP) Forms for Type Approval applications. These forms replace the trademark authorization letter to improve efficiency and accuracy in approvals. The new IP Forms categorize trademark declarations based on whether the applicant has obtained authorization from the trademark/brand owner. For applicants who have been authorized, the required documents include evidence of a registration certificate issued by the Intellectual Property Corporation of Malaysia (MyIPO). Or an equivalent foreign organization, along with an Intellectual Property (IP) Authorization Letter (eTAC/FOR/01-8). On the other hand, if the applicant has not obtained written consent and authorization to use the trademark/brand, they must submit the Intellectual Property (IP) Undertaking form issued by the applicant (eTAC/FOR/01-9). Importantly, these new forms are effective immediately and will be used for all new projects. They mark a significant shift in SIRIM's approach. The organization can now accept brands/trademarks that have not been officially authorized by the brand owner. However, in such cases, the importer must provide a written declaration accepting responsibility. Furthermore, the new Brand name authorization process requires both the Brand owner and the Importer to co-sign the Brand name authorization letter. This updated procedure aims to enhance transparency and accountability in the approval process for Type Approval applications, ultimately benefiting both applicants and consumers in Malaysia. Simplifying SIRIM Certification with 360Compliance Navigating the latest SIRIM and MCMC certification requirements can be complex, especially when introducing new Intellectual Property (IP) Forms. 360Compliance is here to simplify this process for you. Our team knows the latest SIRIM updates, including the new eTAC/FOR/01-8 and eTAC/FOR/01-9 forms. We provide comprehensive support, ensuring your Type Approval applications are complete, accurate, and compliant with the latest regulations. From obtaining the necessary authorizations to submitting the correct IP Forms, we manage every step of the process efficiently. Partner with 360Compliance to streamline your SIRIM certification journey, minimize delays, and maximize compliance. Contact us today to ensure your products easily meet Malaysia's certification standards.
    india
    India Regulatory Updates
    March 21, 2024
    India TEC issued a notification in January 2024 regarding generic exemptions for products without available test labs.  In January 2024, India's Telecommunications Engineering Centre (TEC) issued a significant notification regarding generic exemptions due to the absence of available test laboratories within the country. These exemptions represent a crucial development, indicating that specific parameters no longer require the submission of test reports if customers cannot provide them. It's important to note that while these exemptions are in place, ILAC reports for CE/FCC are still subject to regulations based on the specific product category. This means that evaluation criteria for these reports vary depending on the nature of the product. Furthermore, TEC has specified product categories that continue to accept ILAC reports. Notably, the validation for these exemptions has been extended until June 30, 2024, with the potential for further extensions based on the evolving circumstances. These updates underscore TEC's commitment to adapting regulations to facilitate market access while maintaining stringent quality standards in the telecommunications sector. TEC approves testing exemptions for several product categories under their mandatory testing and certification program The Telecommunications Engineering Centre (TEC), under the Ministry of Communications, recently issued a notification regarding the approval of test requirements exemptions for certain product categories that necessitate mandatory testing and certification. This development signifies a significant step towards streamlining regulatory processes and promoting efficiency in the telecommunications sector. By exempting certain products from rigorous testing requirements, TEC aims to facilitate faster market access for manufacturers while maintaining high standards of quality and safety. This initiative aims to reduce costs and accelerate the introduction of innovative products to benefit industry stakeholders and consumers. How 360Compliance Can Streamline TEC Certification? 360Compliance offers expert guidance for navigating TEC certification complexities, especially with recent updates. We're adept in TEC requirements and ILAC report evaluations, ensuring compliance. Our understanding of exemption criteria and certification process management aids manufacturers and distributors in adjusting smoothly. Partnering with us secures strategic advantages for quicker market access, keeping with India's telecom quality standards. We simplify compliance, focusing on your innovation and growth in a changing regulatory landscape.